  • UHV-300 CT PT വോൾട്ട്-ആമ്പിയർ സ്വഭാവ അനലൈസർ

    ദിUHV-300 CT PT വോൾട്ട്-ആമ്പിയർ സ്വഭാവ അനലൈസർ is essential for protection relay testing, substation maintenance, and transformer diagnostics. Its ability to automatically generate excitation curves, ratio errors, and winding resistance makes it a powerful tool for ensuring grid reliability.

    main


    Key Features

    1、Comprehensive Testing Capabilities

    CT Testing: Excitation characteristics, ratio, polarity, winding resistance, burden, and saturation analysis.

    PT Testing: Volt-ampere (V-I) curves, excitation current, accuracy verification.

    2、High-Precision Measurements

    Measures excitation current, knee-point voltage, turns ratio, and phase error.

    Supports 5A/1A CTs and PTs with multiple voltage ranges.

    3、Built-in Power Supply & Auto Testing

    Integrated variable voltage/current source (up to 300V or higher, depending on model).

    Automatic test sequence for quick and efficient analysis.

    4、Graphical Display & Data Storage

    LCD touchscreen for real-time V-I curve plotting.

    Stores test results for comparison and reporting.

    5、Portable & User-Friendly

    Lightweight design for field use.

    Supports USB/Bluetooth for data transfer and PC software integration.


    Typical Applications

    1、CT/PT Verification – Ensures compliance with IEC 60044, IEEE C57.13, and other standards.

    2、Saturation Testing – Determines the knee-point voltage and excitation characteristics.

    3、Fault Diagnosis – Detects short-circuited turns, open circuits, or core degradation.

    4、Commissioning & Maintenance – Validates transformer performance before and after installation.


    How It Works

    1、Excitation Test (V-I Curve)

    Applies increasing voltage to the CT/PT secondary and records excitation current.

    Plots the magnetization curve to identify knee-point voltage (Vk).

    2、Ratio & Polarity Test

    Injects a test current into the primary and measures secondary output to verify turns ratio & polarity.

    3、Winding Resistance Test

    Uses 4-wire Kelvin method for accurate resistance measurement of windings.

    4、Burden Test

    Checks the actual load connected to the CT/PT secondary.


    Advantages Over Traditional Methods

    1、Faster & Safer – No need for manual voltage injection or separate meters.

    2、More Accurate – Digital processing eliminates human error in curve plotting.

    3、Comprehensive Reporting – Generates test certificates for compliance.


    Safety Considerations

    1、De-energize CT/PT before testing.

    2、Ensure proper grounding.

    3、Follow manufacturer’s test limits to avoid overheating.

    നിങ്ങൾക്ക് ഇതുകൂടി ഇഷ്ടപ്പെട്ടേക്കാം

    • എന്തെങ്കിലും ചോദ്യങ്ങളുണ്ടോ!

      ഏത് സമയത്തും ഞങ്ങളെ ബന്ധപ്പെടാൻ മടിക്കരുത്
      ഞങ്ങളെ സമീപിക്കുക
    • ഞങ്ങളെ സന്ദർശിക്കുക

      ബിൽഡിംഗ് 6, ഒപ്റ്റിക്‌സ് വാലി ഒപ്റ്റിക്കൽ-മെക്കാനിക്കൽ ഇൻഡസ്ട്രിയൽ പാർക്ക്, 84 ഗാക്‌സിൻ 5 റോഡ്,
      ഈസ്റ്റ് ലേക്ക് ന്യൂ ടെക്‌നോളജി ഡെവലപ്‌മെന്റ് സോൺ, വുഹാൻ സിറ്റി, ഹുബെയ് പ്രവിശ്യ, ചൈന

    • ഞങ്ങൾക്ക് ഇമെയിൽ ചെയ്യുക

      qiao@hvtest.cc

    • ഞങ്ങളെ വിളിക്കൂ

      +86-15871365102