qiao@hvtest.cc15871365102
  • SMG2000E Double Clamps Digital Phase Meter

    SMG2000E Double Clamps Digital Phase Meter is a high-precision, hand-held, two-channel instrument designed to measure voltage, current and phase measurement on site.

    Product Details of SMG2000E Double Clamps Digital Phase Meter


    ഉൽപ്പന്ന ആമുഖം

    The Double Clamps Digital Phase Meter is a portable, high-precision instrument for on-site voltage, current, and phase measurements. It enables safe, non-intrusive testing (no need to disconnect lines) and can measure phase differences (U-U, I-I, U-I), phase sequence, transformer wiring groups, differential protection systems, and meter connections. With fully insulated dual-channel inputs, it prevents short circuits and equipment damage. The high-contrast LCD (up to 25mm characters) features a 70° adjustable viewing angle for optimal readability. Ideal for field diagnostics with reliability and ease of use.


    ഉൽപ്പന്ന സവിശേഷതകൾ

    1、Compact & Handheld Design – Portable and user-friendly.

    2、Wide Measurement Range – Measures current (10mA–10A) and voltage (3V–500V) without breaking the circuit.

    3、High-Contrast LCD – 25mm-tall characters with 70° adjustable tilt for optimal visibility.

    4、Intuitive Function Switch – Quickly toggle between voltage, current, and phase measurements.

    5、High-Precision Clamp Sensors – 0.1mA current & 0.1V resolution (patented technology).

    6、Low Power Consumption – Energy-efficient design with battery voltage monitoring.


    ഉൽപ്പന്ന പാരാമീറ്ററുകൾ

    Reference to working conditions

    പരിസ്ഥിതി താപനില(23±5)℃
    പരിസ്ഥിതി ഈർപ്പം(45~75)% RH
    Measured signal waveformSine wave、β=0.02
    Measured signal frequency(50±0.2)Hz
    The position of the measured current-

    carrying conductor at the clamp mouth

    any
    The amplitude of The measured signal when

    measuring The phase

    100~220V、0.5~1.5A
    External reference frequency electromagnetic

    field interference

    Should be avoided

    Measurement error of AC voltage

    Limit of quantityറെസലൂഷൻBasic error limit
    20V0.01V±(0.3% reading +0.2% range)
    200V0.1V
    500V1V


    Measurement error of ac current

    Limit of quantityറെസലൂഷൻBasic error limit
    200mA0.1mA±(0.3% reading +0.2% range)
    2എ1mA
    10എ10mA

    Voltage input circuit impedance when u1-u2 phase is measured:40KΩ

    പരിധിറെസലൂഷൻBasic error limit
    0~360°±2°

    Rated working condition

    പരിസ്ഥിതി താപനില(0~40)℃
    പരിസ്ഥിതി ഈർപ്പം(20~80)% RH
    Measured signal waveformSine wave、β=0.05
    Measured signal frequency(50±0.5)Hz
    The position of the measured current-

    carrying conductor at the clamp mouth

    any
    The amplitude of The measured signal when

    measuring The phase

    U1-U2 phase: 30V ~ 500V
    I1-I2 phase: 10mA ~ 10.00A
    U1-I2 phase or I1-U2 phase: 10V ~ 500V, 10mA ~ 10.00A
    External reference frequency electromagnetic

    field interference

    Should be avoided
    Limit of rated operating errorUnder the above rated working conditions, the rated working error limit of each measured shall not exceed twice the corresponding basic error limit

    Other technical features

    Display digitThree and a half
    സാമ്പിൾ നിരക്ക്3 times per second
    വൈദ്യുതി വിതരണംSingle 9V laminated battery, The power supply current is less than 5mA
    മൊത്തത്തിലുള്ള അളവുകൾCase size192×95×55mm3
    Clamp shell size140×42×20mm3
    താടിയെല്ലിന്റെ വലിപ്പംΦ7mm×9mm
    ഭാരംBody280g
    Test forceps2×200g
    സംഭരണ ​​വ്യവസ്ഥകൾതാപനില-10℃~50℃







    നിങ്ങൾക്ക് ഇതുകൂടി ഇഷ്ടപ്പെട്ടേക്കാം

    • എന്തെങ്കിലും ചോദ്യങ്ങളുണ്ടോ!

      ഏത് സമയത്തും ഞങ്ങളെ ബന്ധപ്പെടാൻ മടിക്കരുത്
      ഞങ്ങളെ സമീപിക്കുക
    • ഞങ്ങളെ സന്ദർശിക്കുക

      ബിൽഡിംഗ് 6, ഒപ്റ്റിക്‌സ് വാലി ഒപ്റ്റിക്കൽ-മെക്കാനിക്കൽ ഇൻഡസ്ട്രിയൽ പാർക്ക്, 84 ഗാക്‌സിൻ 5 റോഡ്,
      ഈസ്റ്റ് ലേക്ക് ന്യൂ ടെക്‌നോളജി ഡെവലപ്‌മെന്റ് സോൺ, വുഹാൻ സിറ്റി, ഹുബെയ് പ്രവിശ്യ, ചൈന

    • ഞങ്ങൾക്ക് ഇമെയിൽ ചെയ്യുക

      qiao@hvtest.cc

    • ഞങ്ങളെ വിളിക്കൂ

      +86-15871365102