qiao@hvtest.cc15871365102
  • Wuhan UHV after-sales service team provides after-sales guidance for Guilin Iron and Steel Company

    Recently, the Wuhan UHV after-sales service team was invited by Guilin Iron and Steel Company to conduct after-sales training for UHV-135kVA/108kV variable frequency series resonant withstand voltage device, UHV-1200 microcomputer relay protection tester, UHV-20A DC resistance rapid tester, UHV-645 oil chromatography analyzer, UHV-660 oil moisture analyzer, UHV-680A automatic insulating oil dielectric strength tester and other equipment.

     

    HTY_7510

    After arriving at Ertang Industrial Concentration Zone, Pingle County, Guilin City, the technicians communicated with Ou Gong, the person in charge of the customer company, on the spot as soon as possible, and confirmed that the after-sales training would officially start the next day.

     

    On the day of the test, the oil chromatography analyzer was first commissioned. The oil chromatography analyzer is composed of the analyzer host, air generator, hydrogen generator, 5 9 high-purity nitrogen cylinders (also known as carrier gas), standard gas cylinders, oscillators, computers, and other parts. The carrier gas connection and oxygen interface and hydrogen interface of the analyzer are connected to the air generator, hydrogen generator, and 5 9 high-purity nitrogen cylinders respectively. The signal and data terminals of the analyzer are connected to the computer. So, the preparation of our connection part is complete.

     

    After that, the chromatograph is made with a standard gas template, and the corresponding chromatography software is opened after the computer is turned on. When the data of the analyzer reaches the set data, use a 1 ml injector with an injection caliper, take 1 ml of standard gas, inject it into the chromatograph, and wait for the chromatograph to run automatically and complete the test. The test results are then kept as standard gas template data.

     

    HTY_2769

    The final step is to perform an oil sample test. Put the oil sample with 5 ml of nitrogen into the oscillator, wait for the oscillator to complete the static, heating, and oscillation, or use the 1 ml injector to extract 1 ml of the oscillated oil sample gas, inject it into the chromatograph and wait for the chromatograph to complete the analysis. In this way, the entire chromatograph is tested.

     

    Subsequently, the technicians carried out detailed and detailed training and guidance services for other equipment on site. In fact, the operation of the equipment is not difficult, the key is to be proficient in the use of the equipment, after 1 day of on-site learning, the customer test personnel have been able to fully grasp the operation of the equipment. So far, this after-sales service journey has also come to a successful conclusion!

    നിങ്ങൾക്ക് ഇതുകൂടി ഇഷ്ടപ്പെട്ടേക്കാം

    • എന്തെങ്കിലും ചോദ്യങ്ങളുണ്ടോ!

      ഏത് സമയത്തും ഞങ്ങളെ ബന്ധപ്പെടാൻ മടിക്കരുത്
      ഞങ്ങളെ സമീപിക്കുക
    • ഞങ്ങളെ സന്ദർശിക്കുക

      ബിൽഡിംഗ് 6, ഒപ്റ്റിക്‌സ് വാലി ഒപ്റ്റിക്കൽ-മെക്കാനിക്കൽ ഇൻഡസ്ട്രിയൽ പാർക്ക്, 84 ഗാക്‌സിൻ 5 റോഡ്,
      ഈസ്റ്റ് ലേക്ക് ന്യൂ ടെക്‌നോളജി ഡെവലപ്‌മെന്റ് സോൺ, വുഹാൻ സിറ്റി, ഹുബെയ് പ്രവിശ്യ, ചൈന